PROFIBUS DP / CAN Gateway
GT200-DP-CA V5.1
909-977-2988
          WhatsApp
               
       
        
        WhatsApp
        
        
        
        	
       
        +1-909-977-2988
        The gateway GT200-DP-CA can connect any CAN2.0A/2.0B devices to PROFIBUS DP network.
- 
Technical Specification
 - 
  
Order Information
 - 
Download
 - 
  
Quick Start Guide
 - 
Selection Guide
 - 
Case Study
 - 
Related Products
 - 
    
Warranty & Service
 
Technical Specifications:
- PROFIBUS DP Features
    
- I/O Capacity:                  
Input: ≤244 Bytes
Output: ≤244 Bytes - Slot Configuration:Configuration mode: GSD V5.1                             
CAN2.0A: 64 slots
CAN2.0B: 42 slots (DP master dependent) - Software Configuration: GSD V4.0 parameter settings
        
- size1: 16 Bytes input+ouput
 - size2: 15 Bytes input+ouput
 
 - Communication Parameters
        
- Baud rate: 9.6Kbps ~ 12Mbps
 - Station address: 1-126
 - Update time: ≤1ms (1Mbps)
 
 
 - I/O Capacity:                  
 - CAN Features
    
- Supported versions: CAN2.0A/2.0B
 - Frame filtering: Enabled in DP config mode
 - Buffer capacity: 200 CAN frames
 - Baud rate: 1M, 500K, 250K, 125K, 100K, 62.5K, 31.25K, 20K, 10K
 
 - General
    
- Power supply: 24VDC ±42% (11-30V)
 - Current consumption: ≤90mA @24V
 - ESD: 15kV HBM
 - Galvanic isolation: 3kVrms
 
 - Physical Features
    
- Dimensions: 1 in*4 in*3.5 in (25mm*100mm*90mm)
 - Mounting: 35mm DIN rail
 - Protection class: IP20
 - Temperature: -40°C to +70°C (-40°F to +158°F)
 - Humidity: 5-95% non-condensing
 
 